Hello!
I am implementing a new installation of FIM 2010 R2 CM in a test environment.
The test environment is "half-production", as it was built to be as close as possible to the active production environment.
I have 2 DC servers (2008r2 sp1), a CA server, an MSSQL 2008 R2 server, and an application server for the FIM installation.
I have done everything that's written in the "Test Lab Guide" document (blogs.technet.com/b/tlgs/archive/2010/11/04/test-lab-guide-demonstrate-fim-cm-2010.aspx), and when I reached the part of "Perform FIM CM subscriber tasks",
When renewing sets of certificates, issuing a temporary or permanent smartcard, everything works perfectly, IF AND ONLY IF the operation is done via the fim portal on the fim application server itself!
If I go to the portal from a regular station (Win7, Win XP, or even another 2008r2sp1 server), I get one of the following errors:
- The RPC server is unavailable
- The version of OLE on the client and server machines does not match
I can't find any relevant log on the CA, end-station, FIM server or the DC for that matter, to help me figure out what's happening.
It seems as though the requests don't even "go out" from the station/server to the FIM or to the CA server.
How can I debug this? What can I check?
I already set all of the debugging levels to "4" in the web.config file, and edited the registry according to some post I found regarding FIM logging.
Kind Regards,
Marom.